Calibration Management Software

Find my fit

Calibration management software organises instrument identities, planned calibration work, results and the records supporting their status. It helps the responsible team find what needs attention and recover what happened to a particular instrument.

A due-date list can be enough for reminders, while a larger programme may need detailed histories, external laboratory records and links to the work using the equipment. Those are different depths of control.

Track instrument history, due work and release decisionsCollapse introduction

Choose around the measurements and operating process the organisation actually manages. A stored certificate or current calendar date alone does not establish that an instrument is suitable for every intended use.

Help me choose Filters

Products

6 products

How products are ordered

Default order places promoted products before other software because of commercial placement. Within both groups, the same data quality formula determines order. Positions inside each group cannot be purchased. Ranking methodology

All other software

Qualcy Quality Modules

Qualcy Systems

Modular eQMS software that lets quality teams control documents, CAPA, nonconformances, audits and calibration with role-based workflows and e-signatures.

Key details 3
Checks
  • Out-of-tolerance detection for calibrated gages and equipment
Traceability
Partial supportBuilt in
What you can do
  • Apply auditable, traceable e-signatures to records
  • Identify products and services potentially affected when a failed gage was in use
Traceability
  • Auditable and traceable e-signatures
  • PDF prints with time stamps and individual traceability
View product
Evidence checked 2026-11-02Data quality 34.1 / 100

PMM.Net

CAQ AG

PMM.Net is the calibration and gauge management module of CAQ.Net: it helps quality teams plan, perform and document inspections and calibrations of measuring equipment and prove gauge and measurement-system capability.

Key details 3
Checks
  • Attributive, quantitative and calculated inspection characteristics
  • Inspection plans per VDI/VDE/DGQ 2618 with fit tables and inspection standards
Traceability
Full supportBuilt in · Paid add-on
What you can do
  • Trace each gauge through gauge histories and inspection histories, with inspection plan versions and approval status
  • Record every change to data with date, time, user and workstation via the optional AuditTrail.Net add-on
Traceability
  • Gauge histories and inspection histories with location of use and storage
  • Inspection plan versions with approval status
View product
Evidence checked 2026-11-02Data quality 33.5 / 100

IndySoft

IndySoft

Calibration management software that helps quality teams, commercial labs and precision manufacturers schedule calibrations, keep audit-ready records and track equipment, tools and maintenance in one system.

Key details 3
Checks
  • pass/fail data point readings
  • automatic uncertainty calculation
Traceability
Partial supportBuilt in
What you can do
  • Search reference standards, calibration certificates and historical events linked to equipment
Methods
  • Name
    AIAG Measurement System Analysis studies
    Description
    R&R, bias, linearity and stability studies
View product
Evidence checked 2026-10-31Data quality 29.6 / 100

Datalyzer Gage Management

Datalyzer

Web-based gage management that tracks instruments, schedules calibrations and runs MSA studies for manufacturing quality teams.

Key details 3
Traceability
Full supportBuilt in
What you can do
  • Manage internal and external calibrations with traceability, including measurement and master uncertainty
  • Link external calibration certificates to calibrations so they are available during audits
Calibration Management
Full supportBuilt in
What you can do
  • Manage internal and external calibrations
  • Use calibration work instructions and document calibration results
Calibration Scheduling
Full supportBuilt in
What you can do
  • Schedule calibration activities automatically from defined intervals
  • Track calibration due dates and full calibration history per gage
View product
Evidence checked 2026-11-02Data quality 28.9 / 100

MOX

Calibration laboratories and regulated manufacturers manage measurement assets, work orders and calibration records in one system, with measurement uncertainty calculated during the calibration itself.

Key details 3
Traceability
Full supportBuilt in
Calibration Management
Full supportBuilt in
Calibration Scheduling
Partial supportBuilt in
View product
Evidence checked 2026-10-21Data quality 26.8 / 100

tracefii

Metquay

Helps asset owners and gage users avoid missed calibration due dates by consolidating asset status, due dates and certificates in one cloud platform.

Key details 3
Traceability
Partial supportBuilt in
What you can do
  • Keep latest calibration certificate, last calibration date and next due date per asset
Not included
  • Detailed traceability chains to standards are not documented
Calibration Management
Partial supportBuilt in · Integration
What you can do
  • Track calibration due dates
  • Store calibration certificates
  • Calibration-status dashboard and health flags
  • Reminders
  • Track calibration job status with a vendor's calibration management software via integration
Not included
  • Lab-side quotes, orders, invoices and uncertainty calculations are not listed as tracefii features
Calibration Scheduling
Partial supportBuilt in
What you can do
  • Track exact next calibration due date per asset
  • View assets by due-date status Good, Warning, Danger
  • On-demand calibration reminders
Not included
  • Automated scheduling rules are not documented
View product
Evidence checked 2026-10-23Data quality 25.7 / 100

Filter software

Calibration management software starts with instrument identity

The record needs to identify the item being controlled and distinguish it from similar equipment. A useful identity survives a move between departments or an external service visit. Location, responsible person and relevant history then help the team find the instrument and interpret its record. A shared spreadsheet may be workable for a small collection; a dedicated tool becomes useful when scheduled work, movements and several contributors make that history difficult to maintain. The required depth follows the programme, not the number of optional fields in a database.

Scheduling and completed calibration are separate records

A planned date tells staff when work is expected. The completed event needs the actual result and supporting context, including the relevant procedure or external report. The team should understand whether the system is only organising laboratory work or also collecting detailed measurement data. A reminder does not perform the calibration, and attaching a certificate does not by itself establish metrological traceability. Traceability concerns the measurement result and its supporting chain; suitability for a particular use requires its own assessment.

Intervals and release rules therefore need owners with the appropriate competence. The software should preserve the configured basis and approved changes rather than present one vendor’s default schedule as the right policy for every instrument.

An unexpected result needs an impact review

A result outside the organisation’s accepted limits can require the instrument to be held for review and earlier work to be considered. The record is useful when responsible staff can recover previous results, relevant dates and any links to jobs or equipment. That evidence helps them determine the scope of the assessment. It should not automatically declare every earlier result valid or invalid because one status changed. Keeping the observation, decision and any resulting action distinguishable makes the outcome explainable to the next reviewer.

Corrected reports also need context. The latest certificate should not erase which earlier version supported a release or another recorded decision.

Include laboratory handoffs and the cost of maintaining the records

External providers, barcode labels and connected asset or production systems can make the programme easier to run when the references remain consistent. Someone still needs to reconcile returned equipment and records that do not match. Migration, historical attachments, permissions, exports and ongoing setup belong in the proposal alongside licences. The system supports the measurement-management process; laboratory accreditation, calibration procedures and fitness for the intended application require their own qualified evaluation.

Add a product

Search to find a product.

Privacy choices

Choose what to allow.

You can change your choice here at any time. Refusing optional analytics does not limit the catalog.

AdvertisingAdSense is not currently enabled. Advertising choices will be available through its consent platform before ads are activated.Not active

Cookie details · Privacy rights